Page view 8
Temperature –Response data relationship:
TEMPERATURE RESPONSE VALUE (binary) RESPONSE VALUE (hex)
+25.0625°C
0000 0001 1001 0001 0191H
+10.125°C
0000 0000 1010 0010 00A2H
+0.5°C
0000 0000 0000 1000 0008H
+0°C
0000 0000 0000 0000 0000H
-0.5°C
1111 1111 1111 1000 FFF8H
-10.125°C
1111 1111 0101 1110 FF5EH
Example: T = RemoteVariableGet (1, 68)
This command has assigned the temperature from sensorCUE-W (with the address 68) to the
T variable.
Reference = 2 the lighting level value
The expected response value range is ( 1 - 30000).
The lowest values mean the highest lighting levels and the highest values mean dark.
The typical expected return values are as follows:
For straight full light the return values are below 100
For bright room the return values are about 700-800
For dark room the return values are about 3500-5000
Example: Light = RemoteVariableGet (2, 47)
This command has assigned the lighting level from sensorCUE-W (with the address 47) to the Light
variable.